The following table contains known issues, scheduled bug fixes, and feature improvements for the Analogue Camera Adapter.
For other information, click on the below links:
Description: Fixed in: 01192002 Analogue Camera Adapter V2.0C When the Analogue Camera Adapter is connected to the Apalis Evaluation Board in combination with an Apalis iMX6 module, in some limited cases the obtained picture shows quality issues. The problem was mostly seen with Apalis Evaluation Board in combination with Apalis iMX6 modules, but it could also show with other combinations or custom carrier boards. This is due to low signal drive strength of the data signals. In V2.0B series resistors R22 and R33 have been changed from 47R to 22R (Resistor 22 ohm 63mW 5% 0603) to improve the signal quality. In some limited cases the signal strength still may be still too low. That is why we additionally shortened the cable to 50mm in V2.0C.