struct
_CAN_MESSAGE_EXT
|
void |
CANGetLibVersion (DWORD *pVerMaj, DWORD *pVerMin, DWORD *pBuild) |
DWORD |
InitSJA1000 (DWORD device, DWORD base, DWORD interruptGPIO, DWORD waterMark, DWORD bufferSize) |
void |
DeInitSJA1000 (DWORD device) |
void |
CANReInitialise (DWORD device) |
BOOL |
CanWriteDescriptor (DWORD device, DWORD descr, DWORD mask) |
DWORD |
CanReadDescriptor (DWORD device) |
DWORD |
CanReadMask (DWORD device) |
BOOL |
CanReset (DWORD device) |
BOOL |
CanSetBaudrate (DWORD device, DWORD baud) |
BOOL |
CanTransmitMessage (DWORD device, CAN_MESSAGE_EXT *msg) |
DWORD |
CANReceiveMessages (DWORD device, CAN_MESSAGE_EXT *msg, DWORD numberOfMsg, DWORD timeout) |
DWORD |
GetCanStatus (DWORD device) |
void |
PrintMessage (CAN_MESSAGE_EXT *msg) |
Structure for extended frame types (29 Bit adress-range). Set "frametype" to "STANDARD" or "EXTENDED". The RTR (Remote-Frame) flag and data length code are now in seperate variables for better hardware independence !
void CANGetLibVersion |
( |
DWORD * |
pVerMaj, |
|
|
DWORD * |
pVerMin, |
|
|
DWORD * |
pBuild |
|
) |
|
|
Returns the library version.
- Parameters:
-
[out] |
VersionMajor |
Returns the major version number. Set this parameter to NULL if not required. |
[out] |
VersionMinor |
Returns the minor version number. Set this parameter to NULL if not required. |
[out] |
Build |
Returns the build number. Set this parameter to NULL if not required. |
- Return values:
-
DWORD CanReadDescriptor |
( |
DWORD |
device |
) |
|
Read the Acceptance Code
- Parameters:
-
[in] |
device |
CAN Device ID |
- Return values:
-
DWORD CanReadMask |
( |
DWORD |
device |
) |
|
Read the Mask
- Parameters:
-
[in] |
device |
CAN Device ID |
- Return values:
-
DWORD CANReceiveMessages |
( |
DWORD |
device, |
|
|
CAN_MESSAGE_EXT * |
msg, |
|
|
DWORD |
numberOfMsg, |
|
|
DWORD |
timeout |
|
) |
|
|
Receive CAN messages
- Parameters:
-
[in] |
device |
CAN Device ID |
[out] |
msg |
pointer to CAN_MESSAGE_EXT array sufficient to hold numberOfMsg messages |
[in] |
numberOfMsg |
Number of messages to wait for |
[in] |
timeout |
Timeout value in milliseconds, use INFINITE to wait forever |
- Return values:
-
Number |
messages received, 0 = timeout |
void CANReInitialise |
( |
DWORD |
device |
) |
|
Reinitialise the CAN Controller/n Clears any unserviced interrupts.
- Parameters:
-
[in] |
device |
CAN Device ID |
- Return values:
-
BOOL CanReset |
( |
DWORD |
device |
) |
|
Reset the CanChip and clear all buffers
- Parameters:
-
[in] |
device |
CAN Device ID |
- Return values:
-
TRUE,: |
Success, FALSE: Error |
BOOL CanSetBaudrate |
( |
DWORD |
device, |
|
|
DWORD |
baud |
|
) |
|
|
Set the Baudrate./n 1000, 800, 500, 250, 125, 100, 50, 20, 10 kBaud./n All other settings set the baud to 125 kBaud
- Parameters:
-
[in] |
device |
CAN Device ID |
[in] |
baud |
Baudrate |
- Return values:
-
TRUE,: |
Success, FALSE: Error |
Send a CAN Message
- Parameters:
-
[in] |
device |
CAN Device ID |
[in] |
msg |
Pointer to a CAN message structure |
- Return values:
-
TRUE,: |
Success, FALSE: Error |
BOOL CanWriteDescriptor |
( |
DWORD |
device, |
|
|
DWORD |
descr, |
|
|
DWORD |
mask |
|
) |
|
|
Write the Acceptance Code and Mask Registers./n Library is running in dual mode (AFM =0)./n For more information see the SJA1000 documentation.
- Parameters:
-
[in] |
device |
CAN Device ID |
[in] |
descr |
32 bit acceptance code |
[in] |
mask |
32 bit acceptance mask |
- Return values:
-
TRUE,: |
Success, FALSE: Error |
void DeInitSJA1000 |
( |
DWORD |
device |
) |
|
Release CAN Controller
- Parameters:
-
[in] |
device |
CAN Device ID |
- Return values:
-
DWORD GetCanStatus |
( |
DWORD |
device |
) |
|
Return the CAN Status
- Parameters:
-
[in] |
device |
CAN Device ID |
- Return values:
-
0 |
= OK/n Test with CAN_ERROR and CAN_OVERRUN_HW Constants |
DWORD InitSJA1000 |
( |
DWORD |
device, |
|
|
DWORD |
base, |
|
|
DWORD |
interruptGPIO, |
|
|
DWORD |
waterMark, |
|
|
DWORD |
bufferSize |
|
) |
|
|
Initialise CAN Controller
- Parameters:
-
[in] |
device |
CAN Device ID |
[in] |
base |
SJA1000 Chip Base Address |
[in] |
interruptGPIO |
GPIO Number of the interrupt from the SJA1000 |
[in] |
waterMark |
Number of messages received before the library signals reception of messages. |
[in] |
bufferSize |
Size of the receive buffer in CAN_MESSAGE_EXT messages |
- Return values:
-
0 |
= Success 1 = SoC not supported -1 = Could not create ISR_CoM struct -2 = Could not map Chip Base Address -4 = Could not create Mutex -5 = Could not enter reset mode -6 = Could not enter normal mode -7 = Could not create receive buffer -8 = Could not create Interrupt Service Thread -9 = Could not initialise GPIO |
Print the contents of the supplied CAN_MESSAGE_EXT message
- Parameters:
-
[in] |
msg |
Pointer to a CAN_MESSAGE_EXT instance |
- Return values:
-